OEM / ODM · Gas & oil burner ignition transformers

Built to your drawing.
Or to our platform.

Potted, dry-type ignition transformers from 4 kV to 26 kV peak — 120 V and 230 V, 15 to 48 mA, 20% to 100% duty. Drawing to first article in six weeks. Production in four.

Free samples · NDA before drawings · Plant in Wujiang, Suzhou

Drawing of a potted ignition transformer with twin porcelain output terminals and slotted mounting feet
Fig. 1 — Potted case, twin porcelain terminals, epoxy encapsulated
Output4 – 26 kV peak
Input120 / 230 V · 50/60 Hz
Current15 – 48 mA
Duty20 / 50 / 100 %
1992Potted transformer production since
1995First UL 506 OEM program for the US market
50,000Ignition transformers per year, in-house
100%Hipot and function tested before packing
4 wkStandard production lead time
01 — Product range

Four inductive classes.
Plus electronic.

Most burner platforms sit in one of these four bands. We build all four on the same EI-core, vacuum-impregnated, epoxy-potted platform — so a new rating is a tooling change, not a new factory.

4 – 6 kV

Compact & commercial

Gas burners, wall-hung boilers, packaged rooftop units, small industrial burners.

Peak
2×4 / 6 kV
Current
20 – 25 mA
Duty
100 %
Specification →
7 – 8 kV

Industrial gas & light oil

Industrial gas trains, dual-electrode burners, packaged boilers, process heaters.

Peak
7 / 8 kV
Current
15 – 40 mA
Duty
20 – 100 %
Specification →
10 – 15 kV

Heavy oil & large furnace

Heavy-oil burners, large industrial furnaces, utility and process boiler fronts.

Peak
10 / 15 kV
Current
22 – 35 mA
Duty
20 – 100 %
Specification →
20 – 26 kV

High-energy ignition

Large heavy-oil burners, cold-start and high-moisture duty, oversized electrode gaps.

Peak
20 / 26 kV
Current
40 – 48 mA
Duty
20 / 50 %
Specification →
05 — Electronic ignition

Same job, half the size.

A ferrite step-up driven by a switching module instead of a 50/60 Hz EI stack: 4 – 20 kV peak, 12/24 V DC or 120/230 V AC input, 100 % continuous duty, constant spark rate. The part new burner platforms are being designed around — and one we take OEM and ODM programs on, on the same terms as the inductive range.

Output
4 – 20 kV peak
Input
12/24 V DC · 120/230 V AC
Spark rate
20 – 100 Hz
Duty
100 % continuous
Format
Potted module or board in your housing
Electronic range →
02 — Cross-reference

Start from a part
you already run.

Give us the housing you have and the rating you need. The full table maps common burner-market ratings to our platform models, so a first conversation starts from dimensions and figures instead of a blank page.

Kmwell modelBandInputOutput (peak)CurrentDuty
KTX-4064–6230 V2 × 4 kV20 mA100%
KTX-6064–6120 V6 kV25 mA100%
KTX-7507–8230 V2 × 7.5 kV40 mA50%
KTX-152510–15230 V15 kV25 mA20%
KTX-204020–26230 V20 kV40 mA20%

Reference ratings describe the market segment and typical figures, not electrical identity with any specific product. See the full 13-model table →

03 — How you buy

Three ways to place
a program with us.

A burner manufacturer with a full engineering department needs a build-to-print supplier. A distributor launching a private label needs a designer. Both come off the same line — only the boundary of responsibility moves.

A / build to print

Your drawing, our tooling

You send the drawing and the approved specification. We tool, build and test to it. No design fee, and the drawing stays yours.

  • ·Quotation against drawing in 3 working days
  • ·First article with dimensional and electrical report
  • ·Tooling owned by you, or amortised to zero
B / platform + custom

Our platform, your variables

Start from a KTX platform and change the core stack, ratio, terminals, lead length, potting colour and mounting. Shortest path to a differentiated part.

  • ·Engineering review inside 5 working days
  • ·3D step model and housing drawing supplied
  • ·NRE quoted per variant, waived at volume
C / private label

Your brand, no Kmwell mark

Nameplate, carton, insert, barcode and drop-ship all carry your identity. Nothing on the part or packaging points back to us.

  • ·Label and packaging artwork handled in-house
  • ·Carton and pallet spec matched to your DC
  • ·No Kmwell branding on part, box or paperwork

Compare the three models, the customisation matrix and tooling terms →

04 — Quality

Certification is
the entry ticket.

Burner OEMs do not buy transformers — they buy a component that will not hold up their own listing. Every certificate below is either in place or running against a dated plan.

UL 506Specialty transformers · North AmericaOwn recognition in progress · supplied under customer files since 1995
EN 61558-2-3Transformers for gas and oil burners · EUDesign and type testing complete · report on request
ISO 9001:2015Quality management systemCertified · certificate on request

Full compliance list, test regime and document package →

05 — Process

Six weeks, five moves.

The schedule is fixed at quotation, not discovered at shipment. Every step has a named deliverable you can hold us to.

Day 0NDA & drawing

Two-way NDA inside a day. Send a drawing, a sample, or a rating and a photo.

Day 3Quote

Price, tooling, lead time and MOQ against the drawing — with the duty cycle stated.

Day 10Samples

Two to five units, free, with dimensional and electrical report.

Day 30First article

FAI report, PPAP level 3 if required, and a production slot reserved.

Week 6Shipment

First production lot out of the door. Repeats run in three weeks.

See the plant, the process flow and open capacity →

Send the drawing. We answer in three days.

Request a quote